DataSheet.es    


PDF GP10 Data sheet ( Hoja de datos )

Número de pieza GP10
Descripción Paperless Recorder
Fabricantes Yokogawa 
Logotipo Yokogawa Logotipo



Hay una vista previa y un enlace de descarga de GP10 (archivo pdf) en la parte inferior de esta página.


Total 21 Páginas

No Preview Available ! GP10 Hoja de datos, Descripción, Manual

<<Contents>> <<Index>>
General
Specifications
GS 04L52B01-01EN
GP10/GP20
Paperless Recorder
(Portable type)
GX90XA/GX90XD/GX90YD I/O Modules
OVERVIEW
The GP10/GP20 are portable type paperless recorders
that display real-time measured data on a touch
screen and save data on an external storage medium
(SD card).
● The number of measurement data is a maximum
of 48 channels in GP10, and a maximum of 100
channels in GP20.
● The GP10/GP20 have the large internal memory
(GP10/GP20: 500MB), and prolonged record and
preservation are possible.
● As the input signal, a DC voltage, thermocouple,
resistance temperature detector, or contact signal
can be set to each channel.
● Input and output have module structure and it can
extend them easily. (GP10: max. 3, GP20: max. 10)
● A module type is three types, an analog input, a
digital input, and a digital output.
● The intuitive operation by flick, pinch in, pinch out,
and swipe are possible.
● The past trend under recording can be seamlessly
displayed on a trend screen.
● Moreover, the measurement data of the time
specified on the calendar screen can be searched
and displayed.
● Various functions, such as a freehand message,
a PDF/Excel output of a report file, a direct output
to a network printer, a scale movement of a trend
display, and a buzzer sound, are equipped.
● It can be hooked up to network via Ethernet, which
enables to inform by Email and to monitor on Web
site as well as to transfer files by using FTP. Also,
it can communicate with Modbus/RTU or Modbus/
TCP.
● A setup of GP can be performed on-line from the
web browser on PC. A setup by off-line is also
possible.
● Universal Viewer software allows a PC to
display waveforms on its screen and to print out
waveforms.
MAIN UNIT SPECIFICATIONS
■ FUNCTIONAL SPECIFICATION
Input Specifications
Please see "INPUT/OUTPUT MODULE
SPECIFICATIONS."
Display Functions
Display groups:
Number of groups; GP10: 30, GP20: 50
Number of channels that can be assigned to
each group; GP10: 10, GP20: 20
Scan interval: 100*, 200*, 500 ms*, 1, 2, 5 s
* Cannot be specified if an electromagnetic relay
scanner type (Type Suffix Code: -T1) analog input
module is in use.
GP10
GP20
Display color (Trend/Bar graph/Digital display):
Channel: Select from 24 colors
A desired display color can be selected freely
using its RGB value.
Background: Select from white or black
Display type:
● Trend display (T-Y)
Display method:
Direction: Horizontal, vertical
Trend interval: 5*, 10*, 15*, 30 s/div, 1, 2, 5,
10, 15, 20, 30 min/div, 1, 2, 4, 10 h/div
* Cannot be specified if an electromagnetic relay
scanner type analog input module is in use.
Trend line width: Thick, normal, thin
Scale; GP10: Max. 6, GP20: Max. 10
Current value bar graph, color scale band,
and alarm point marks can be displayed on
the scale.
Moving scale; Scale can be moved on any
waveform.
A bitmap image scale can be attached.
Others; Grid (Auto, 4 to 12), Trip line, Message,
Zone display, Partial expanded display
● Historical trend display (T-Y display)
Redisplays the display data or event data in the
internal memory or external storage medium
Time axis operation: The time axis can be
reduced or expanded.
Data search: Waveforms from the internal
memory can be displayed through the
specification of a date and time, calendar, each
summary
Moving scale; A bitmap image scale can be
attached.
All historical trends can be displayed in one
screen.
● Bar graph display
Direction: Vertical or horizontal
Scale: Display a scale for each channel
Color scale band, and alarm point marks can
be displayed on the scale.
Yokogawa Electric Corporation
2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan
GS 04L52B01-01EN
©Copyright Octorber 2012
7th Edition May. 7, 2013

1 page




GP10 pdf
<<Contents>> <<Index>>
HARDWARE SPECIFICATIONS
(MAIN UNIT)
Display
Display unit*:
GP10: 5.7-inch TFT color LCD (640 × 480 dots)
GP20: 12.1-inch TFT color LCD (800 × 600 dots)
* A small number of missing or steady-on LCD
pixels and minor variations in brightness
uniformity is a normal display characteristic and
not a malfunction.
Touch screen:
4 wire resistive touch screen
Construction
• Material;
Case: Metal plate
Bezel and display cover: Polycarbonate
• Color;
Case: Smoke blue
Bezel: Charcoal grey light
• External dimensions:
When installing modules
GP10: 144(W) × 168(H) × 248(D) mm
GP20: 288(W) × 318(H) × 248(D) mm
When uninstalling modules
GP10: 144(W) × 168(H) × 197(D) mm
GP20: 288(W) × 318(H) × 197(D) mm
(D: depth from the panel mounting plane)
• Weight:
GP10: Approx. 1.9 kg, GP20: Approx. 5.7 kg
(excluding modules)
Power Supply
• Rated supply voltage: 100 to 240 VAC
• Allowable power supply voltage range: 90 to 132,
180 to 264 VAC
• Rated power supply frequency: 50/60 Hz
• Power consumption:
Supply LCD backlight
voltage
off
Normal
operation
Maximum
100 V AC GP10: 16 VA
GP20: 28 VA
GP10: 20 VA GP10: 48 VA
GP20: 34 VA GP20: 90 VA
240 V AC GP10: 24 VA
GP20: 38 VA
GP10: 30 VA GP10: 60 VA
GP20: 45 VA GP20: 110 VA
* The following combinations are assumed for LCD
backlight off and normal operation.
GP10: 1 AI module, 1 DO module, 1 DI module
GP20: 5 AI modules, 4 DO modules, 1 DI module
• Module power supply voltage: The total allowable
power consumption of respective modules is up
to 6 W in the GP10 and up to 20 W in the GP20.
• Allowable interruption time: Less than 1 cycle of
the power supply frequency
5
Isolation
• Insulation resistance: Between the Ethernet,
RS-422/485, and each insulation terminals and
earth: 20 MΩ or greater at 500 VDC
• Withstand voltage:
Between the power terminal and earth: 3000 V
AC at 50/60 Hz for one minute
Between the contact output terminal and earth:
3000 VAC at 50/60 Hz for one minute
Between the input/output modules and earth:
Depends on the specification of I/O module.
• Ground; Grounding resistance: 100 Ω or less
• Isolation:
FAIL output terminal
Ethernet port
RS-422/485 terminal
Input and output module terminal
Power terminal
Input and output module internal circuit
Earth (PE) terminal
RS-232 terminal
SD card slot
Internal circuit
USB port
The circuits divided by lines are insulated mutually.
Safety and EMC Standards
• CSA: CSA22.2 No.61010.1, installation
category II (*1), and pollution degree 2 (*2), and
CSA-C22.2 NO. 61010-2-030-12
• UL: UL61010-1, UL 61010-2-030 (CSA NRTL/C)
• CE:
EMC directive
EN61326-1 compliance, Class A Table 2
EN61000-3-2 compliance
EN61000-3-3 compliance
EN55011 Class A Group 1
Low voltage directive
EN61010-1, EN 61010-2-030
Installation category II (*1)
Pollution degree 2 (*2)
Measurement category II (*3)
• C-Tick: EN55011 compliance, Class A Group 1
• KC marking: Electromagnetic wave interference
prevention standard, electromagnetic wave
protection standard compliance
*1 Installation category (overvoltage category) II:
Describes a number which defines a transient
overvoltage condition.
Implies the regulation for impulse withstand
voltage.
“II” applies to electrical equipment which
is supplied from the fixed installation like a
distribution board.
*2 Pollution degree 2:
Describes the degree to which a solid, liquid,
or gas which deteriorates dielectric strength or
surface resistivity is adhering.
“2” applies to normal indoor atmosphere.
Normally, only non-conductive pollution occurs.
*3 Measurement category: Depends on the
specification of each modules
All Rights Reserved. Copyright © 2012-2013, Yokogawa Electric Corporation
GS 04L52B01-01EN
May. 7, 2013-00

5 Page





GP10 arduino
<<Contents>> <<Index>>
11
Continued
RTD
DI
Input Type
Range
Pt100
JPt100
Cu10 GE
Cu10 L&N
Cu10 WEED
Cu10 BAILEY
Cu10 (20 °C)
alpha=0.00392
Cu10 (20 °C)
alpha=0.00393
Cu25 (0 °C)
alpha=0.00425
Cu53 (0 °C)
alpha=0.00426035
Cu100 (0 °C)
alpha=0.00425
J263B
-200.0 to 850.0 °C
-150.00 to 150.00 °C
-200.00 to 550.00 °C
-150.00 to 150.00 °C
-200.0 to 300.0 °C
-200.0 to 300.0 °C
-200.0 to 300.0 °C
-200.0 to 300.0 °C
-200.0 to 300.0 °C
-200.0 to 300.0 °C
-200.0 to 300.0 °C
-50.0 to 150.0 °C
-50.0 to 150.0 °C
0.0 to 300.0 K
Ni100 (SAMA)
Ni100 (DIN)
Ni120
Pt25
Pt50
Pt200 WEED
Cu10 GOST
Cu50 GOST
Cu100 GOST
Pt46 GOST
Pt100 GOST
Level
Contact
-200.0 to 250.0 °C
-60.0 to 180.0 °C
-70.0 to 200.0 °C
-200.0 to 550.0 °C
-200.0 to 550.0 °C
-100.0 to 250.0 °C
-200.0 to 200.0 °C
-200.0 to 200.0 °C
-200.0 to 200.0 °C
-200.0 to 550.0 °C
-200.0 to 600.0 °C
Measurement accuracy (digital display)
A/D integration time: 16.7ms or more A/D integration time: 1.67ms (fast sampling mode)
±(0.15 % of rdg + 0.3 °C)
±(0.3 % of rdg + 1.5 °C)
±(0.2 % of rdg + 2.0 °C)
guaranteed range
Cu10 GE: -70.0 to 170.0 °C
Cu10 L&N: -75.0 to 150.0 °C
Cu10 WEED: -200.0 to 260.0 °C
Other range: -200.0 to 300.0 °C
±(0.4 % of rdg + 6.0 °C)
guaranteed range
Cu10 GE: -70.0 to 170.0 °C
Cu10 L&N: -75.0 to 150.0 °C
Cu10 WEED: -200.0 to 260.0 °C
Other range: -200.0 to 300.0 °C
Max. resolution
of digital display
0.1 °C
0.01 °C
0.1 °C
0.01 °C
0.1 °C
±(0.3 % of rdg + 0.8 °C)
±(0.15 % of rdg + 0.8 °C)
±(0.2 % of rdg + 1.0 °C)
±1.0 K
Less than 40.0 K: ±3.0 K
±(0.15 % of rdg + 0.4 °C)
±(0.5 % of rdg + 3.0 °C)
±(0.3 % of rdg + 4.0 °C)
±(0.4 % of rdg + 5.0 °C)
±3.0 K
Less than 40.0 K: ±9.0 K
±(0.3 % of rdg + 2.0 °C)
0.1 °C
0.1 °C
0.1 °C
0.1 K
0.1 °C
±(0.15 % of rdg + 0.8 °C)
±(0.3 % of rdg + 0.6 °C)
±(0.3 % of rdg + 4.0 °C)
±(0.6 % of rdg + 3.0 °C)
0.1 °C
0.1 °C
±(0.2 % of rdg + 2.0 °C)
±(0.4 % of rdg + 6.0 °C)
±(0.15 % of rdg + 0.6 °C)
±(0.3 % of rdg + 4.0 °C)
±(0.15 % of rdg + 0.3 °C)
±(0.3 % of rdg + 1.5 °C)
±(0.3 % of rdg + 0.8 °C)
±(0.6 % of rdg + 4.0 °C)
±(0.15 % of rdg + 0.3 °C)
±(0.3 % of rdg + 2.0 °C)
Threshold level (Vth=2.4 V) Accuracy: ±0.1 V
Less than 1 kΩ: 1(ON), More than 100 kΩ: 0(OFF) (parallel capacitance of 0.01 μF or less)
0.1 °C
0.1 °C
0.1 °C
0.1 °C
0.1 °C
-
-
Measurement accuracy at scaling: measurement accuracy at scaling (digits) = measurement accuracy (digits) x scaling
span (digits)/measurement span (digits) + 2 digits
* Rounding up decimal places
• Burnout detection: Burnout upscale, downscale,
or OFF selectable (for each channel).
Available input: TC, RTD, Standard signal
TC; Normal: 2 kΩ or less., Burnout: 200 kΩ
or more (parallel capacitance of 0.01 μF or
less)
Detection current: Approx. 10 μA
RTD; Normal: wiring resistance or less,
Burnout: 200 kΩ or more (parallel
capacitance of less than 0.01 μF or less)
Standard signal: Normal: Within measuring
range, Burnout: -10% or less or 110% or
more of the specified span.
• Input external resistance:
DC voltage, thermocouple input: 2 kΩ or
below
Resistance temperature detector input: 10 Ω
or below in each wire (Same resistance in
three wires)
• Input bias current: ±10 nA or less (when burnout
function does not work)
• Measured current (for RTD): Approx. 1 mA
• Input resistance:
10 MΩ or more for TC/DC voltage (1 V range or
less) input
Approx. 1 MΩ for DC voltage (2 V range or
more)/standard signal input
• Allowable signal source resistance: 2 kΩ or less
for TC/DC voltage (1 V range or less) input
• Effect of signal source resistance:
±10 μV/1kΩ or less for TC/DC voltage (1 V range
or less) input
±0.15 %/1kΩ or less for DC voltage (2 V range or
more)/standard signal input
• Allowable wiring resistance: Max. 10 Ω per line
for RTD input (conductor resistance between the
three lines shall be equal)
• Effect of wiring resistance: ±0.1°C/10 Ω for RTD
input (conductor resistance between the three
lines shall be equal)
• Allowable input voltage:
±10 V DC for TC/DC voltage (1 V range or less)/
RTD/DI input
±60 V DC for DC voltage (2 V range or more) input
All Rights Reserved. Copyright © 2012-2013, Yokogawa Electric Corporation
GS 04L52B01-01EN
May. 7, 2013-00

11 Page







PáginasTotal 21 Páginas
PDF Descargar[ Datasheet GP10.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
GP10Paperless RecorderYokogawa
Yokogawa
GP100(GP100 - GP110) 1 AMP HIGH RELIABILITY SILICON DIODESDIOTEC Electronics Corporation
DIOTEC Electronics Corporation
GP100PPTC ThermistorsGoodpoly
Goodpoly
GP1001Glass Passivated RectifiersTaiwan Semiconductor
Taiwan Semiconductor

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar