ACS550 Schematic ( PDF Datasheet ) - ABB

Teilenummer ACS550
Beschreibung Low voltage AC drives
Hersteller ABB
Logo ABB Logo 




Gesamt 16 Seiten
ACS550 Datasheet, Funktion
Low voltage AC drives
ABB standard drives
ACS550
0.75 to 355 kW / 1 to 500 hp
Catalog






ACS550 Datasheet, Funktion
Ratings, types, voltages and construction
ACS550 - 01 - 03A3 - 4 + B055
Type code
Drive’s type code (shown above and in column 7 of the tables
on the right side) identifies your drive by construction, current
rating and voltage range. Once you have selected the type
code, the frame size (column 8) can be used to determine the
drives dimensions, shown on the next page.
Construction
“01” within the type code (shown above) varies depending on
the drive mounting arrangement, and power rating.
01 = wall-mounted
02 = free-standing
Voltages
The ACS550 is available in two voltage ranges:
4 = 380 to 480 V
2 = 208 to 240 V
Insert either “4” or “2”, depending on your chosen voltage,
into the type code shown above.
3-phase supply voltage 380 to 480 V
Wall-mounted units
Ratings
Normal use
Heavy-duty use
Type code
Frame
size
PN
kW
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
PN
hp
1.5
2
3
4
5.4
7.5
10
15
20
25
30
40
50
60
100
125
150
150
200
200
I2N
A
3.3
4.1
5.4
6.9
8.8
11.9
15.4
23
31
38
45
59
72
87
125
157
180
205
246
290
Phd
kW
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Phd
hp
1
1.5
2
3
4
5.4
7.5
10
15
20
25
30
40
60
75
100
125
125
150
200
I2hd
A
2.4
3.3
4.1
5.4
6.9
8.8
11.9
15.4
23
31
38
45
59
72
96
125
156
162
192
246
ACS550-01-03A3-4
ACS550-01-04A1-4
ACS550-01-05A4-4
ACS550-01-06A9-4
ACS550-01-08A8-4
ACS550-01-012A-4
ACS550-01-015A-4
ACS550-01-023A-4
ACS550-01-031A-4
ACS550-01-038A-4
ACS550-01-045A-4
ACS550-01-059A-4
ACS550-01-072A-4
ACS550-01-087A-4
ACS550-01-125A-4
ACS550-01-157A-4
ACS550-01-180A-4
ACS550-01-195A-4
ACS550-01-246A-4
ACS550-01-290A-4
R1
R1
R1
R1
R1
R1
R2
R2
R3
R3
R3
R4
R4
R4
R5
R6
R6
R6
R6
R6
Normal use vs heavy-duty use. For the majority of pump, fan and conveyor
applications, select “Normal use” figures. For high overload requirements, select
“Heavy-duty use” figures. If in doubt contact your local ABB sales office or your
drives distributor.
PN for kW = Typical motor power in 400 V at normal use
PN for hp = Typical motor power in 460 V at normal use
Phd for kW = Typical motor power in 400 V at heavy-duty use
Phd for hp = Typical motor power in 460 V at heavy-duty use
Free-standing units
200 300 368
250 400 486
280 450 526
315 500 602
355 500 645
160 250 302
200 350 414
250 400 477
280 450 515
315 500 590
ACS550-02-368A-4
ACS550-02-486A-4
ACS550-02-526A-4
ACS550-02-602A-4
ACS550-02-645A-4
R8
R8
R8
R8
R8
3-phase supply voltage 208 to 240 V
Wall-mounted units
Ratings
Normal use
Heavy-duty use
Type code
Frame
size
PN
kW
0.75
1.1
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0
PN
hp
1.0
1.5
2.0
3.0
5.0
7.5
10.0
15.0
20.0
25.0
30.0
40.0
50.0
60.0
75.0
100
I2N
A
4.6
6.6
7.5
11.8
16.7
24.2
30.8
46.2
59.4
74.8
88.0
114
143
178
221
248
Phd
kW
0.75
0.75
1.1
1.5
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
Phd I2hd
hp A
0.8 3.5
1.0 4.6
1.5 6.6
2.0 7.5
3.0 11.8
5.0 16.7
7.5 24.2
10.0 30.8
15.0 46.2
20.0 59.4
25.0 74.8
30.0 88.0
40 114
50 150
60 178
75 192
ACS550-01-04A6-2
ACS550-01-06A6-2
ACS550-01-07A5-2
ACS550-01-012A-2
ACS550-01-017A-2
ACS550-01-024A-2
ACS550-01-031A-2
ACS550-01-046A-2
ACS550-01-059A-2
ACS550-01-075A-2
ACS550-01-088A-2
ACS550-01-114A-2
ACS550-01-143A-2
ACS550-01-178A-2
ACS550-01-221A-2
ACS550-01-248A-2
R1
R1
R1
R1
R1
R2
R2
R3
R3
R4
R4
R4
R6
R6
R6
R6
6 ABB standard drives ACS550 | Catalog

6 Page









ACS550 pdf, datenblatt
Cooling and fuses
Cooling
ACS550 is fitted with cooling air fans. The cooling air must
be free from corrosive materials and not above the maximum
ambient temperature of 40 °C (50 °C with derating). For more
specific environmental limits see page 5.
Fuse connections
Standard fuses can be used with ABB standard drives. For
input fuse connections see tables below.
Cooling air flow 380 to 480 V units
Type code
Frame size
ACS550-01-03A3-4 R1
ACS550-01-04A1-4 R1
ACS550-01-05A4-4 R1
ACS550-01-06A9-4 R1
ACS550-01-08A8-4 R1
ACS550-01-012A-4 R1
ACS550-01-015A-4 R2
ACS550-01-023A-4 R2
ACS550-01-031A-4 R3
ACS550-01-038A-4 R3
ACS550-01-045A-4 R3
ACS550-01-059A-4 R4
ACS550-01-072A-4 R4
ACS550-01-087A-4 R4
ACS550-01-125A-4 R5
ACS550-01-157A-4 R6
ACS550-01-180A-4 R6
ACS550-01-195A-4 R6
ACS550-01-246A-4 R6
ACS550-01-290A-4 R6
ACS550-02-368A-4 R8
ACS550-02-486A-4 R8
ACS550-02-526A-4 R8
ACS550-02-602A-4 R8
ACS550-02-645A-4 R8
Heat dissipation Air flow
W
40
52
73
97
127
172
232
337
457
562
667
907
1120
1440
1940
2310
2810
3050
3260
3850
6850
7850
7600
8100
9100
BTU/Hr
137
178
249
331
434
587
792
1151
1561
1919
2278
3098
3825
4918
6625
7889
9597
10416
11134
13125
23394
26809
25955
27663
31078
m3/h
44
44
44
44
44
44
88
88
134
134
134
280
280
280
350
405
405
405
405
405
1220
1220
1220
1220
1220
ft3/min
26
26
26
26
26
26
52
52
79
79
79
165
165
165
205
238
238
238
238
238
718
718
718
718
718
Cooling air flow 208 to 240 V units
Type code
Frame size
ACS550-01-04A6-2 R1
ACS550-01-06A6-2 R1
ACS550-01-07A5-2 R1
ACS550-01-012A-2 R1
ACS550-01-017A-2 R1
ACS550-01-024A-2 R2
ACS550-01-031A-2 R2
ACS550-01-046A-2 R3
ACS550-01-059A-2 R3
ACS550-01-075A-2 R4
ACS550-01-088A-2 R4
ACS550-01-114A-2 R4
ACS550-01-143A-2 R6
ACS550-01-178A-2 R6
ACS550-01-221A-2 R6
ACS550-01-248A-2 R6
Heat dissipation
W BTU/Hr
55 189
73 249
81 276
118 404
161 551
227 776
285 973
420 1434
536 1829
671 2290
786 2685
1014 3463
1268 4331
1575 5379
1952 6666
2189 7474
Air flow
m3/h
44
44
44
44
44
88
88
134
134
280
280
280
405
405
405
405
ft3/min
26
26
26
26
26
52
52
79
79
165
165
165
238
238
238
238
Recommended input protection fuses for 380 to 480 V units
Type code
Frame size IEC fuses
UL fuses
A Fuse type *) A Fuse type
ACS550-01-03A3-4 R1
ACS550-01-04A1-4 R1
ACS550-01-05A4-4 R1
ACS550-01-06A9-4 R1
ACS550-01-08A8-4 R1
ACS550-01-012A-4 R1
ACS550-01-015A-4 R2
ACS550-01-023A-4 R2
ACS550-01-031A-4 R3
ACS550-01-038A-4 R3
ACS550-01-045A-4 R3
ACS550-01-059A-4 R4
ACS550-01-072A-4 R4
ACS550-01-087A-4 R4
ACS550-01-125A-4 R5
ACS550-01-157A-4 R6
ACS550-01-180A-4 R6
ACS550-01-195A-4 R6
ACS550-01-246A-4 R6
ACS550-01-290A-4 R6
ACS550-02-368A-4 R8
ACS550-02-486A-4 R8
ACS550-02-526A-4 R8
ACS550-02-602A-4 R8
ACS550-02-645A-4 R8
10 gG
10 gG
10 gG
10 gG
10 gG
16 gG
16 gG
25 gG
35 gG
50 gG
50 gG
63 gG
80 gG
125 gG
160 gG
200 gG
250 gG
250 gG
250 gG
315 gG
400 gG
500 gG
630 gG
630 gG
800 gG
10 UL Class T
10 UL Class T
10 UL Class T
10 UL Class T
15 UL Class T
15 UL Class T
20 UL Class T
30 UL Class T
40 UL Class T
50 UL Class T
60 UL Class T
80 UL Class T
90 UL Class T
125 UL Class T
175 UL Class T
200 UL Class T
250 UL Class T
250 UL Class T
250 UL Class T
315 UL Class T
400 UL Class T
500 UL Class T
630 UL Class T
630 UL Class T
800 UL Class T
Recommended input protection fuses for 208 to 240 V units
Type code
Frame size IEC fuses
A Fuse type *)
ACS550-01-04A6-2 R1
10 gG
ACS550-01-06A6-2 R1
10 gG
ACS550-01-07A5-2 R1
10 gG
ACS550-01-012A-2 R1
16 gG
ACS550-01-017A-2 R1
25 gG
ACS550-01-024A-2 R2
25 gG
ACS550-01-031A-2 R2
40 gG
ACS550-01-046A-2 R3
63 gG
ACS550-01-059A-2 R3
63 gG
ACS550-01-075A-2 R4
80 gG
ACS550-01-088A-2 R4
100 gG
ACS550-01-114A-2 R4
125 gG
ACS550-01-143A-2 R6
200 gG
ACS550-01-178A-2 R6
250 gG
ACS550-01-221A-2 R6
315 gG
ACS550-01-248A-2 R6
315 gG
UL fuses
A Fuse type
10 UL Class T
10 UL Class T
10 UL Class T
15 UL Class T
25 UL Class T
30 UL Class T
40 UL Class T
60 UL Class T
80 UL Class T
100 UL Class T
110 UL Class T
150 UL Class T
200 UL Class T
250 UL Class T
300 UL Class T
350 UL Class T
Free space requirements
Enclosure type Space above
Wall mounted
Free standing
mm
200
200
Space below
mm
200
0
Space on left/right
mm
0
0
12 ABB standard drives ACS550 | Catalog
*) According to IEC-60269 standard

12 Page





SeitenGesamt 16 Seiten
PDF Download[ ACS550 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
ACS550Low voltage AC drivesABB
ABB
ACS550-01Low Voltage AC Drives User ManualABB
ABB
ACS550-CCPackaged Drive User ManualABB
ABB
ACS550-U1Low Voltage AC Drives User ManualABB
ABB

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche