E2CA-XIR5A Datasheet, Funktion
Inductive Proximity Sensor
E2CA
Linear Output Proximity Sensor with
High-accuracy Resolution
Resolution is 0.05% of the maximum sensing
distance. The model with a sensing distance of
1.2 mm ensures a resolution of 0.6 m.
Models with response frequencies ranging from 10
to 3 kHz are available.
The M30-size model ensures a sensing distance of
10 mm.
Satisfies IEC IP67 requirements, thus detecting the
displacement of metal objects without being
influenced by water and oil spray.
The E2CA has a standard linear output of 4 to
20 mA and connects to the Linear Discrimination
Unit, Digital Panel Meter, and I/O Unit of the
Programmable Controller.
The E2CA’s compact amplifier can be plugged into
surface mounting sockets thus greatly reducing
wiring effort and ensuring easy mounting.
Ordering Information
Shield
Size
Shielded
M8
M12
M18
M30
Sensing
distance (Sn)
0.3 to 1.5 mm
0.4 to 2 mm
1 to 5 mm
2 to 10 mm
Response frequency
Linear output Switching
output
10 kHz
1 kHz
10 kHz
800 Hz
5 kHz
350 Hz
3 kHz
100 Hz
Sensor Unit
Amplifier Unit
DC AC
E2CA-XIR5A
E2CA-X2A
E2CA-X5A
E2CA-X10A
E2CA-AL4C
E2CA-AL4D
E2CA-AL4E
E2CA-AL4F
E2CA-AN4C
E2CA-AN4D
E2CA-AN4E
E2CA-AN4F
1






E2CA-XIR5A Datasheet, Funktion
E2CA
Nomenclature
Selector and Adjuster Settings
(1) Operation Mode Selector
OUTPUT The switching output transistor turns ON
NO NC when there is sensing object detection.
OUTPUT The switching output transistor turns ON
NO NC when there is no sensing object detection.
(1) Operation mode selector
(2) Cord length compensation selector
SENSITIVITY adjuster
Used to adjust the sensing distance of
switching output.
E2CA
POWER indicator (red LED)
ON when power is supplied to the E2CA.
OPER indicator
ON when the switching output of the POWER
indicator is detected.
(ON when detected, OFF when not detected)
SPAN indicator
Indicates the linear range of green
LED output current.
Linear output current adjuster (20 mA)
Linear output current adjuster (4 mA)
(2) Cord Length Compensation Selector
Set the selector to 3 m or 5 m according to the
length of the Sensor cord in use.
CABLE
3m 5m
CABLE
3m 5m
A cord length of 3 m is selected.
A cord length of 5 m is selected.
Linear Output Adjustment (LINEARITY Adjuster)
Step
Positioning ---
1
2
20% of rated
sensing distance
Standard object
3
Rated sensing distance
Remarks
---
Standard
object
LINEARITY ---
adjuster
---
Adjustment
procedure
4 mA
Connect an ammeter across terminals 1
Place the standard
and 2.
object at 20% of the
rated sensing distance
away from the Sensor
Shielded cord
P2CF-11
Switching
output
(photocoupler
Unit. Turn the 4 mA
LINEARITY adjuster
output)
slowly clockwise (the
output current is
E2CA-Aj4j
increased) or
Amplifier Unit
P2CF-11
Front-connecting Socket
counterclockwise (the
output current is
decreased) to set the
Note: This illustration shows the Sensor
output current to 4 mA.
Unit connected to the Amplifier Unit
(SPAN indicator is ON.)
with the P2CF-11 Front-connecting
Socket mounted.
20 mA
Fasten the standard
object at the rated
sensing distance. Turn
the 20-mA LINEARITY
adjuster slowly
clockwise (the output
current is increased) or
counterclockwise (the
output current is
decreased) to set the
output current to 20 mA.
(SPAN indicator is ON.)
To further
improve the
adjustment
accuracy, set
again the
position of the
standard object
in the order of
steps 2 and 3.
Perform minute
adjustment of
the output
current.
6

6 Page









E2CA-XIR5A pdf, datenblatt
E2CA
Enclosed Mounting
If the Y92F-30 Adapter is used, insert the E2CA into the square hole
from the front side of the panel and slide the Y92F-30 onto the E2CA
from the rear side of the E2CA. Then press the Y92F-30 so that the
space between the Y92F-30 and the panel is reduced as much as
possible. Finally, secure the Y92F-30 with screws.
E2CA
Removing the Amplifier Unit
If the Y92F-30 is used, loosen the screws of the Y92F-30, spread
out the hooks, and remove the Y92F-30.
Panel
Y92F-30 Adapter
P3G-11 Back-mounting Socket
Others
The accuracy of the E2CA will vary with the on-site environment.
The resolution, temperature characteristics, and voltage character-
istic linearity are especially affected. Therefore, keep the on-site en-
vironment as suitable for the E2CA as possible.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D77-E1-1 In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Sensors Division
Sensing Devices and Components Division H.Q.
28th Fl., Crystal Tower Bldg.
1-2-27, Shiromi, Chuo-ku,
Osaka 540-6028 Japan
Phone: (81)6-949-6012 Fax: (81)6-949-6021
Printed in Japan
0398-0.5M (0398) a
12

12 Page





SeitenGesamt 12 Seiten
PDF Download[ E2CA-XIR5A Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
E2CA-XIR5AInductive Proximity SensorOmron
Omron

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche