DataSheet.es    


PDF DRS240PS24 Data sheet ( Hoja de datos )

Número de pieza DRS240PS24
Descripción 80-240 Watts AC-DC Converter
Fabricantes XP 
Logotipo XP Logotipo



Hay una vista previa y un enlace de descarga de DRS240PS24 (archivo pdf) en la parte inferior de esta página.


Total 2 Páginas

No Preview Available ! DRS240PS24 Hoja de datos, Descripción, Manual

80-240 Watts
DRS80-240 Series
xppower.com
Ultra Slim Cases
150% Peak Load for 4 seconds
Wide Output Adjustment Range
High Efficiency – Up to 92%
12 V, 24 V & 48 V Versions
Low Output Ripple & Noise
-20 ºC to 70 ºC Operating Temperature
Specification
Input
Input Voltage
• 85-264 VAC
Input Frequency
• 47-63 Hz
Input Current
• 80 W: 2 A at 85 VAC
120 W: 2 A at 85 VAC
240 W: 4 A at 85 VAC
Inrush Current
• 30 A max at 230 VAC
Power Factor
• DRS80 0.6 typical
DRS120 & 240 0.95 typical
Conforms to EN61000-3-2 Class A.
Earth Leakage Current • 1.5 mA maximum
Output
Output Voltage
• See table
Output Voltage Trim • See table
Initial Set Accuracy • ±1% at 50% load
Minimum Load
• No minimum load required
Start Up Delay
• 1 s maximum
Start Up Rise Time
• 20 ms typical
Hold Up Time
• 20 ms minimum at full load and 115 VAC
Line Regulation
• ±0.5%
Load Regulation
• ±1%
Transient Response
• 10% maximum deviation, recovering to
less than 1% within 500 µs for 50% step
load change at 0.2 A/µs
Ripple & Noise
• 100 mV pk-pk maximum, measured with
20 MHz BW
Overvoltage Protection • 12 V output: 16.5-18 V, 24 V output:
29-31.2 V, 48 V output: 57.6-62.4 V
Overload Protection
• 110-150% of rated current, constant
current limit
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
• ±0.02%/°C
General
Efficiency
Isolation
Switching Frequency
Signals
MTBF
• See table
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• DRS80 60-300 kHz variable
DRS120 & DRS240 100 kHz typical PFC
& main converter
• DRS120 & 240: DC OK Volt free contacts
• >200 kHrs to MIL HDBK217F
Environmental
Operating Temperature • -20 ºC to +70 ºC (see derating curves)
Cooling
• Natural covection
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -25 °C to +85 °C
Shock
• IEC68-2-6, 30 g, 11ms half sine, 3 times in
each of 6 axes
Vibration
• IEC68-2-27, 10-500 Hz, 2 g 10
mins/sweep. 60 mins for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022, class B conducted & radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, 4 KV Contact,
8 KV Air Discharge
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, Installation Class 3
Perf Criteria B
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• UL508, EN60950, UL1604 Pending

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet DRS240PS24.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
DRS240PS2480-240 Watts AC-DC ConverterXP
XP

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar