Relion® Protection and Control
REF615R
DPU2000R DNP3 Point List Mitigation Manual
http://www.Datasheet4U.com

1 page




REF615R pdf
Disclaimer
The data, examples and diagrams in this manual are included solely for the concept or
product description and are not to be deemed as a statement of guaranteed properties. All
persons responsible for applying the equipment addressed in this manual must satisfy
themselves that each intended application is suitable and acceptable, including that any
applicable safety or other operational requirements are complied with. In particular, any
risks in applications where a system failure and/or product failure would create a risk for
harm to property or persons (including but not limited to personal injuries or death) shall
be the sole responsibility of the person or entity applying the equipment, and those so
responsible are hereby requested to ensure that all measures are taken to exclude or
mitigate such risks.
This product is designed to be connected and to communicate information and data via a
network interface, which should be connected to a secure network. It is sole responsibility
of person or entityresponsible for network administration to ensure a secure connection to
the network and to establish and maintain any appropriate measures (such as but not
limited to the installation of firewalls, application of authentication measures, encryption
of data, installation of anti virus programs, etc) to protect the product, the network, its
system and the interface against any kind of security breaches, unauthorized access,
interference, intrusion, leakage and/or theft of data or information. ABB is not liable for
damages and/or losses related to such security breaches, unauthorized access, interference,
intrusion, leakage and/or theft of data or information
This document has been carefully checked by ABB but deviations cannot be completely
ruled out. In case any errors are detected, the reader is kindly requested to notify the
manufacturer. Other than under explicit contractual commitments, in no event shall ABB
be responsible or liable for any loss or damage resulting from the use of this manual orthe
application of the equipment.

5 Page





REF615R arduino
1MRS240172-IB A
Section 1 Introduction
Section 1
Introduction
1.1
This manual
DPU2000R was developed by ABB in the 1990s and has served industry successfully for
over a decade. As time went by, some of its hardware components and software design
became obsolete which restrict it to fit into the picture of the future power grid network
communication system. REF615R, as a new generation of ABB IED, offers much broader
network communication capabilities as it implements the state of the art IEC61850
protocol as its primary substation communication protocol.
IEC61850 is an object oriented communication protocol. It models a SCADA system
interests into its associated logical device, logical node, function names and instances, etc.
In this way, it presents every raw data from the field as a unique data attribute represented
by an IEC61850 path.
On top of the basic IEC61850 protocol, the REF615R supports other well respected digital
communication protocols such as modbus and DNP3. However, because of the changes of
the functionality, the data presentation and the hardware structure, the previously defined
DNP3 data points are not one on one translated to the existing IEC61850 data attributes.
Also the evolution of DNP3 protocol to level 2 +, offers some new features and enhances
some previously offered features in DNP3 protocol.
This manual is published to help system integrator to expedite the process of replacing the
DPU2000R with the REF615R. In this manual, the general features change is introduced
in section 2.
The section 3 includes the lookup tables for the DI, counter, AI and control points. An
IEC61850 path will be provided and mapped to the corresponding DPU2000R index as
default mapping if the functionality and data class remain the same between DPU2000R
and REF615R. Otherwise, a mitigation solution will be provided if available.
The section 4 shows the ACT logics that can help obtaining the mitigation result.
This document only covers the mitigation solutions for default DNP3 mapping list of
DPU2000R. To obtain the complete DNP3 point list of REF615R, please refer to the
Feeder Protection and Control REF615R DNP3 Point List Manual.
REF615R
DPU2000R DNP3 Point List Mitigation Manual
5

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet REF615R.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
REF615RDNP3 Point List Mitigation ManualABB
ABB

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar