DATA LOGGER
MODELS DL-1080/1081
USER MANUAL
V1.3xA
INTRODUCTION
CONNECTIONS AND INSTALLATION
MECHANICAL INSTALLATION
ATTACHING AND DETACHING THE FRONT COVER
ATTACHING AND DETACHING THE DISPLAY
ELECTRICAL CONNECTIONS
SAFETY SUMMARY
RECOMMENDATIONS FOR INSTALLATION
POWER SUPPLY
DIGITAL I/O
RELAYS
RS485
AUXILIARY POWER SUPPLY FOR POWERING TRANSMITTERS
ANALOG INPUTS
CONNECTIVITY RESOURCES
FLAGS (LEDS)
INSTALLING THE USB DRIVER
WINDOWS 7
DEFINITION AND SELECTION OF SERIAL PORT (COM) - WINDOWS
CONFIGURATION AND DATA DOWNLOAD SOFTWARE
CONFIGURATION
GENERAL CONFIGURATIONS
RS485 INTERFACE CONFIGURATION
ETHERNET INTERFACE CONFIGURATION
ETHERNET INTERFACE CONFIGURATION - TCP/IP
ETHERNET INTERFACE CONFIGURATION – FTP
ETHERNET INTERFACE CONFIGURATION - SMTP
ETHERNET INTERFACE CONFIGURATION - E-MAIL RECEIVERS
ETHERNET INTERFACE CONFIGURATION - SNMP
ETHERNET INTERFACE CONFIGURATION – HTTP
ETHERNET INTERFACE CONFIGURATION – MODBUS TCP
ANALOG CHANNELS CONFIGURATION
ANALOG CHANNELS CONFIGURATION – CUSTOM CALIBRATION
DIGITAL CHANNELS CONFIGURATION
REMOTE CHANNELS CONFIGURATION
VIRTUAL CHANNELS CONFIGURATION
ALARMS CONFIGURATION
LOG CONFIGURATION
DIAGNOSTICS
DOWNLOAD
DOWNLOAD DATA
DOWNLOAD MANAGER
USING THE STEP-BY-STEP (WIZARD)
PREFERENCES
COMMAND-LINE OPERATION
BATCH FILE
ACTION TYPE
CONNECTION MODE
ACTION PARAMETERS
EXPORT PARAMETERS
DATA LOGGER OPERATION
4
5
5
8
9
10
10
11
11
11
11
12
12
13
15
17
18
18
21
22
23
25
26
27
28
29
30
31
32
33
34
35
37
38
40
43
44
48
50
53
54
57
57
65
65
65
66
66
66
67
68
Free Datasheet http://www.datasheet-pdf.com/

1 page




DL-1080 pdf
AEMC INSTRUMENTS
DATA LOGGERS
CONNECTIONS AND INSTALLATION
When unpacking, remove the insulating film of the Data Logger battery, located below
the chassis according to Fig. 01, before carrying through the electrical wiring and
configuration.
Fig. 01 – Insulating film of the battery
MECHANICAL INSTALLATION
Data Logger chassis can be installed on a 35 mm DIN rail.
For the installation on the rail, you must pull out the two clamps located right below the connections of the channels,
taking care not to remove them, as per Fig. 02.
Note: If necessary, the connector may be removed for installation of DIN rail.
Fig. 02 - DIN rail installation
AEMC® INSTRUMENTS – 99-MAN 100386 v3
5
Free Datasheet http://www.datasheet-pdf.com/

5 Page





DL-1080 arduino
AEMC INSTRUMENTS
DATA LOGGERS
NOTES:
1) An external protection device consisting of a 0.5A slow blow fuse (UL Listed) must be wired near to the Data Logger.
2) A switch or circuit-breaker placed near to the Data Logger shall be used as the disconnecting device.
Fig. 14 - Lower side connections
RECOMMENDATIONS FOR INSTALLATION
Input signal leads must be installed in grounded conduits and away from power or contactor wires.
Instruments must be powered only by an exclusive power supply.
Installing RC filters (47and 100nF, serial) is strongly recommended at contactor coils or any other inductors.
System failure should always be taken into account when designing a control panel to avoid irreversible damage to
equipment or injury to people. The RL1 and RL2 output relays, used as alarms, do not warrant total protection.
Wiring section: minimum gauge 0.14 mm².
POWER SUPPLY
The terminals 25 and 26 are used to supply power to the Data Logger.
DIGITAL I/O
There are eight I/O ports that can be individually configured as inputs or outputs. There is a terminal for the positive
signal of each I/O, and a common negative terminal for all of them (there is no isolation between the channels).
Inputs:
When configured as inputs, they may be connected to voltage outputs (please check the acceptable levels in the
Specifications section), dry-contact outputs and NPN outputs. Care must be taken when connecting multiple outputs
because there is no isolation between the Data Logger inputs.
Fig. 15 - Voltage connection
Fig. 16 - Dry-contact connection
Fig. 17 - NPN Connection
Outputs:
When configured as outputs, they can activate limited power loads (please check the Specifications section).
Fig. 18 - Connection of a load RL to a digital output
RELAYS
The Data Logger has 2 relays that can be used in the activation of electrical loads (please check the Specifications
section). For each relay, there is a common terminal, NC (normally closed) terminal and a NO (normally open) terminal.
AEMC® INSTRUMENTS – 99-MAN 100386 v3
11
Free Datasheet http://www.datasheet-pdf.com/

11 Page







PáginasTotal 70 Páginas
PDF Descargar[ Datasheet DL-1080.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
DL-1080(DL-1080 / DL-1081) DATA LOGGER USER MANUALAEMC
AEMC
DL-1081(DL-1080 / DL-1081) DATA LOGGER USER MANUALAEMC
AEMC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar