2000~6000W Front End Power System R K P - 1 U R a c k S y s t e m
Features :
Universal AC input / Full range
Holds up to 3 power modules
Active current sharing up to 6000W(3 unit) in one 19”rack, 3 rack max.
can be operated in parallel (up to 9 units)
PMBus serial interface
IEC320-C20 or terminal block input
Front-end & rectifier applications
Stackable for system expansion
Low profile: 1U height, 19” rack mount
Hot swappable modules
Output voltage trimming function
3 years warranty
Description :
RCP-2000 rack power system is an advanced 19” rack-mounted power system containing up to 3 hot-swappable RCP-2000 rectifiers and
can deliver up to 6000W in the single rack. Up to 3 racks can be stacked to provide expanded total system capability up to 18,000W that
are especially suitable for the application of servers, information technology equipment, networking, telecommunications, and wide
range of industrial applications using distributed power architecture. Equipped with PMBus communication protocol, RCP-2000 rack
system can be controlled or monitored by external device such as monitoring unit (RCP-CMU-1) or PC.
SELECTION GUIDE
Rack: RKP-1U I C
C: With RCP-CMU-1
-: Without RCP-CMU-1
I: AC Inlet (IEC320-C20)
T: Terminal block
Whole System: RKP-6K1U I C - 12
Output voltage
C: With RCP-CMU-1
-: Without RCP-CMU-1
I: AC Inlet
T: Terminal
SPECIFICATION - Rack System
MODEL
RKP-6K1U -12
RKP-6K1U -24
RKP-6K1U -48
MODULE
RCP-2000-12
RCP-2000-24
RCP-2000-48
RACK
RKP-1UI or RKP-1UT
OUTPUT OUTPUT VOLTAGE
12V
24V
48V
MAX. OUTPUT CURRENT 300A
240A
126A
MAX. OUTPUT POWER Note.6 3600W
5760W
6048W
VOLTAGE RANGE
Note.5 90 ~ 264VAC 127 ~ 370VDC
INPUT
FREQUENCY RANGE
47 ~ 63Hz
AC CURRENT (Typ.)FOR EACH UNIT 13A/115VAC
7A/230VAC
16A/115VAC 11A/230VAC
16A/115VAC 11A/230VAC
LEAKAGE CURRENT
<3.5mA / 230VAC
AUXILIARY POWER
5V @ 0.3A, 12V @ 0.8A
REMOTE ON/OFF CONTROL By electrical signal or dry contact ON:short OFF:open
FUNCTION
REMOTE SENSE
DC OK SIGNAL
AC FAIL SIGNAL
Compensate voltage drop on the load wiring up to 0.5V. "Local Sense"should be connected in order to get the correct output voltage if the "Remote Sense"is not used
The isolated TTL signal out, refer to function manual
The isolated TTL signal out, refer to function manual
OUTPUT VOLTAGE TRIM
Adjustment of output voltage, possible between 90 ~ 110% of rated output
OVER TEMP WARNING
Logic " High" for over temperature warning, refer to function manual, isolated signal
FAN FAIL SIGNAL
The isolated TTL signal out, refer to function manual
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC ISOLATION RESISTANCE
(Note 4) EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.7KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
OTHERS
NOTE
DIMENSION
Rack 483.6*350.8*44(L*W*H)
PACKING
11.5Kg; 1pcs/11.5Kg/2.67CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Output of all the RCP-2000 modules are connected in parallel in the rack.
7. Under parallel operation of more than one rack connecting together, ripple of the output voltage may be higher than the SPEC at light load condition.
It will go back to normal ripple level once the output load is more than 10%.
File Name:RKP-1U RACK SYSTEM-SPEC 2011-05-09
Datasheet pdf - http://www.DataSheet4U.net/

1 page




RKP-1U pdf
www.DataSheet.co.kr
2000~6000W Front End Power System R K P - 1 U R a c k S y s t e m
5.PMBus communication interface
5.1 Interface specification
RCP-2000 support PMBus Rev.1.1 with maximum 100kHz bus speed.
5.2 Device Address (A0~A4)
MSB LSB
1 0 A4 A3 A2 A1 A0
The device address can be defined by using DIP switch and shows below. The DIP switch down position is logic "1" and up position is logic "0".
12345
ON
Module
No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
DIP switch position
1234
ON ON ON ON
OFF ON ON ON
ON OFF ON ON
OFF OFF ON ON
ON ON OFF ON
OFF ON OFF ON
ON OFF OFF ON
OFF OFF OFF ON
ON ON ON OFF
OFF ON ON OFF
ON OFF ON OFF
OFF OFF ON OFF
ON ON OFF OFF
OFF ON OFF OFF
ON OFF OFF OFF
OFF OFF OFF OFF
5
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Module
No.
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
DIP switch position
1234
ON ON ON ON
OFF ON ON ON
ON OFF ON ON
OFF OFF ON ON
ON ON OFF ON
OFF ON OFF ON
ON OFF OFF ON
OFF OFF OFF ON
ON ON ON OFF
OFF ON ON OFF
ON OFF ON OFF
OFF OFF ON OFF
ON ON OFF OFF
OFF ON OFF OFF
ON OFF OFF OFF
OFF OFF OFF OFF
5
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
5.3 Command Summary (ref. to PMBus Rev.1.1)
Command
Code
01h
02h
19h
Command
Name
OPERATION
ON_OFF_CONFIG
CAPABILITY
20h VOUT_MODE
21h VOUT_COMMAND
22h VOUT_TRIM
46h IOUT_OC_FAULT_LIMIT
47h IOUT_OC_FAULT_RESPONSE
79h STATUS_WORD
7Ah STATUS_VOUT
7Bh STATUS_IOUT
7Ch STATUS_INPUT
7Dh STATUS_TEMPERATURE
Transaction
Type
R/W Byte
Read Byte
Read Byte
R Byte
R Word
R/W Word
R/W Word
R Byte
R Word
R Byte
R Byte
R Byte
R Byte
# of data
Bytes
1
1
1
1
2
2
2
1
2
1
1
1
1
Description
Remote ON/OFF control
ON/OFF function configuration
Capabilities of a PMBus device
Define data format for output voltage
(format: Linear, N= -9)
Output voltage setting value
(format: Linear, N= -9)
Output voltage trimming value
(format: Linear, N= -9)
Output overcurrent setting value
Define protection and response when an
output overcurrent fault occurred
Summary status reporting
Output voltage status reporting
Output current status reporting
AC inpit voltage statusreporting
Temperature status reporting
File Name:RKP-1U RACK SYSTEM-SPEC 2011-05-09
Datasheet pdf - http://www.DataSheet4U.net/

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet RKP-1U.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
RKP-1U2000 - 6000W Front End Power SystemMean Well Enterprises
Mean Well Enterprises

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar