DataSheet.es    


PDF E3X-DA-S Data sheet ( Hoja de datos )

Número de pieza E3X-DA-S
Descripción Digital Fiber Sensors
Fabricantes Omron 
Logotipo Omron Logotipo



Hay una vista previa y un enlace de descarga de E3X-DA-S (archivo pdf) en la parte inferior de esta página.


Total 28 Páginas

No Preview Available ! E3X-DA-S Hoja de datos, Descripción, Manual

New Product
Digital Fiber Sensors
E3X-DA-S
www.DataSheet4U.com
An Extensive of Standard Functions
to Support the World's Highest Level of
Stable Detection.
• "GIGA RAY" Giga Power Lighting Element to create a wide variety
of value.
• Power turning to easily set the optimum light level.
• Active Thereshold Control (ATC) reduces incorrect operation due to
dust, oil, or other influences.
• Automatic Power Control (APC) is always enabled to stabilize
emitter power with high accuracy.
Ordering Information
Amplifier Units [Dimensionspage 23]
Type
Appearance
Connecting
method
NPN output
Model
PNP output
Standard
models
Pre-wired
(2 m)
E3X-DA21-S 2M
Wire-saving
connector
E3X-DA7-S
E3X-DA51-S 2M
E3X-DA9-S
Applicable wire-saving connector
(sold separately)
Type
Model
--- ---
Master
connector
Slave
connector
E3X-CN21
E3X-CN22
Ultra-long-term
APC models
Pre-wired
(2 m)
E3X-DA21R-S 2M
Wire-saving
connector
E3X-DA7R-S
E3X-DA51R-S 2M
---
E3X-DA9R-S
Master
connector
Slave
connector
---
E3X-CN21
E3X-CN22
High-speed
response
models
Pre-wired
(2 m)
E3X-DA21F-S 2M
Wire-saving
connector
E3X-DA7F-S
An Wire-saving connector sold separately is required.
E3X-DA51F-S 2M
---
E3X-DA9F-S
Master
connector
Slave
connector
---
E3X-CN11
E3X-CN12
1

1 page




E3X-DA-S pdf
Sensing Distance
E3X-DA-S
www.DataSheet4U.com
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
Screw-shaped model
Sensing
method
Size
Sensing
direction
Model
Tough mode
M3
Straight
E32-T21R 2M
450
Through-
beam
models
M4
Right angle
Straight
E32-T11N 2M
E32-T11R 2M
E32-TC200 2M
2,000
2,000
2,800
E32-T11L 2M
4,000
Right angle E32-C31N 2M
110
M3 E32-D21R 2M
140
Straight
E32-C31 2M
330
M4 E32-D211R 2M
140
Reflective
models
Right angle
E32-D11N 2M
E32-C11N 2M
840
780
E32-D11R 2M
M6
E32-DC200 2M
Straight
E32-CC200 2M
840
1,400
1,400
E32-D11L 2M
1,820
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution Standard
mode
mode
High-speed
mode
300 250 150
1,400
1,000
700
1,400
1,000
700
2,000
1,550
1,000
3,400
2,700
1,740
80 50 46
100 60 40
240 150 100
100 60 40
600 350 240
560 350 320
600 350 240
1,000 600 400
1,000 600 400
1,300 800 520
Super-high-
speed mode
60
280
280
400
700
14
16
44
16
100
100
100
180
180
220
Fiber Unit
Flat model
Sensing
method
Through-
beam
models
Sensing
direction
Top view
Side view
Flat view
Reflective
models
Top view
Side view
Flat view
Size
Standard
Small
Standard
Small
Standard
Small
Standard
Small
Standard
Small
Standard
Small
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
E32-T15XR 2M
2,000
1,400
1,000
700
280
E32-T25XR 2M
450 300 250 150
60
E32-T15YR 2M
750 550 450 260 100
E32-T25YR 2M
170 120 100 50 20
E32-T15ZR 2M
750 550 450 260 100
E32-T25ZR 2M
170 120 100 50 20
E32-D15XR 2M
840 600 350 240 100
E32-D25XR 2M
140 100 60 40 16
E32-D15YR 2M
200 140 100 52 24
E32-D25YR 2M
40 28 16 10
4
E32-D15ZR 2M
200 140 100 52 24
E32-D25ZR 2M
40 28 16 10
4
Fiber Unit
Cylindrical model
Sensing
method
Sensing
direction
Through-
beam
models
Top view
Side view
Reflective
models
Top view
Side view
Size
φ1
φ3
φ1
φ3
φ1.5
φ2
φ3
φ2
φ6
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
E32-T223R 2M
450 300 250 150
60
E32-T12R 2M
2,000
1,400
1,000
700
280
E32-T24R 2M
170 120 100 50 20
E32-T14LR 2M
750 550 450 260 100
E32-D22B 2M
140 100 60 40 16
E32-D32 2M
330 240 150 100
44
E32-D22R 2M
140 100 60 40 16
E32-D32L 2M
700 500 300 200
90
E32-D24R 2M
70 52 30 20
8
E32-D14LR 2M
220 160 100 60 28
Fiber Unit
Model equipped with sleeve
Sensing
method
Sleeve size
Mounting size
Through-
beam
models
φ0.25 × 5
φ0.5 × 40
φ0.9 × 40
φ1.2 × 90
φ3
M3
M4
φ0.5 × 15
φ2
Reflective
models
φ0.8 × 15
φ1.2 × 40
φ3
M3
φ2.5 × 90
M6
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
E32-T333-S5 1M
35 25 20 12
8
E32-T33 1M
150 110 90 50 20
E32-TC200F4R 2M
450 300 250 150
60
E32-TC200BR 2M
2,000
1,400
1,000
700
280
E32-D331 2M
14 10 6 4 2
E32-D33 2M
70 50 30 20
8
E32-DC200F4R 2M
140 100 60 40 16
E32-DC200BR 2M
840 600 350 240 100
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
5

5 Page





E3X-DA-S arduino
E3X-DA-S
www.DataSheet4U.com
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Long distance / Dust resistance (High-power),
Detection through gaps (Narrow vision field)
Sensing distance (unit: mm)
Sensing
method
Type
Sensing direction /
Lens type
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
High-power
(integrated unit)
Top view
Side view
E32-T17L 10M
E32-T14 2M
20,000 1
4,000 2
20,000 1
4,000 2
20,000 1
3,400
10,000
2,250
High-power E32-T11N 2M + E39-F1
4,000 2
4,000 2
3,700
2,400
Ultrahigh-power E32-T11N 2M + E39-F16
4,000 2
4,000 2
4,000 2
4,000 2
High-power E32-T11R 2M + E39-F1
4,000 2
4,000 2
3,700
2,400
Ultrahigh-power E32-T11R 2M + E39-F16
4,000 2
4,000 2
4,000 2
4,000 2
Side view
E32-T11R 2M + E39-F2
725 520 400 250
High-power E32-TC200 2M + E39-F1
4,000 2
4,000 2
4,000 2
2,600
Ultrahigh-power E32-TC200 2M + E39-F16
4,000 2
4,000 2
4,000 2
4,000 2
Side view
E32-TC200 2M + E39-F2
1,170 840 700 450
High-power E32-T11 2M + E39-F1
4,000 2
4,000 2
3,600
2,300
Through-
beam
models
High-power
(with lens unit)
Ultrahigh-power
Side view
High-power
Ultrahigh-power
E32-T11 2M + E39-F16
E32-T11 2M + E39-F2
E32-T11U 2M + E39-F1
E32-T11U 2M + E39-F16
4,000 2
1,150
4,000 2
4,000 2
4,000 2
820
4,000 2
4,000 2
4,000 2
660
3,600
4,000 2
4,000 2
430
2,300
4,000 2
Side view
E32-T11U 2M + E39-F2
1,150 820 660 430
High-power E32-T11NU 2M + E39-F1
4,000 2
2,600
2,000
1,300
Ultrahigh-power E32-T11NU 2M + E39-F16
4,000 2
4,000 2
4,000 2
3,300
High-power E32-T81R-S 2M + E39-F1
4,000 2
2,650
2,100
1,300
Ultrahigh-power E32-T81R-S 2M + E39-F16
4,000 2
4,000 2
3,600
2,300
Side view
E32-T81R-S 2M + E39-F2
500 360 280 180
High-power E32-T61-S 2M + E39-F1
4,000 2
4,000 2
3,400
2,200
Ultrahigh-power E32-T61-S 2M + E39-F16
4,000 2
4,000 2
4,000 2
3,900
Side view
E32-T61-S 2M + E39-F2
840 600 450 300
Narrow vision field
(aperture angle: 4°)
Top view
Side view
E32-T22S 2M
E32-T24S 2M
3,500
2,400
2,500
1,750
1,900
1,300
1,250
870
Reflective
models
High-power
Top view
E32-D16 2M
40 to 1,400 40 to 1,000
40 to 700
40 to 450
1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Super-high-
speed mode
4,000
900
970
1,800
970
1,800
100
1,500
4,000 2
160
930
2,300
160
930
2,300
160
500
1,300
520
900
70
900
1,500
120
500
350
40 to 240
Fiber Unit
Minute object detection (Small-spot model)
Sensing Spot diameter
method
(mm)
Focal length
(mm)
φ0.1 to 0.6
(Variable)
6 to 15
φ0.3 to 1.6
(Variable)
10 to 30
φ0.1
5
7
Reflective
models
φ0.2
φ0.5
17
7
17
φ6 50
φ4
Parallel light
0 to 20
φ3 50
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-high-
speed mode
E32-C42 1M + E39-F3A
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm
E32-C42 1M + E39-F17
E32-C42S 1M
E32-C41 1M + E39-F3A-5
E32-C41 1M + E39-F3B
E32-C31 2M + E39-F3A-5
E32-C31 2M + E39-F3B
E32-L15 2M
E32-C31 2M + E39-F3C
E32-C11N 2M + E39-F18
E32-CC200 2M + E39-F18
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm
Spot diameter of 0.1 mm at 5 mm
Spot diameter of 0.1 mm at 7 mm
Spot diameter of 0.2 mm at 17 mm
Spot diameter of 0.5 mm at 7 mm
Spot diameter of 0.5 mm at 17 mm
Spot diameter of 6 mm at 50 mm
Sensing distance in all mode (40 to 100 mm)
Spot diameter of 4 mm max. at 0 to 20 mm
Spot diameter of 3 mm at 50 mm
Spot diameter of 3 mm at 50 mm
Fiber Unit
Area-sensing (Area beam)
Sensing
method
Area range
Through-
beam
models
Reflective
models
11mm
30mm
11mm
Sensing
direction
Side view
Flat view
Side view
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
E32-T16PR 2M
1,550
1,100
840
560
220
E32-T16JR 2M
1,370 980 750 480 190
E32-T16WR 2M
2,000
1,700
1,300
850
340
E32-D36P1 2M
350 250 150 100
45
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
11

11 Page







PáginasTotal 28 Páginas
PDF Descargar[ Datasheet E3X-DA-S.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
E3X-DA-SDigital Fiber SensorsOmron
Omron

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar