DataSheet39.com

What is DHR-C10?

This electronic component, produced by the manufacturer "LEM", performs the same function as "AC/DC Current transducer".


DHR-C10 Datasheet PDF - LEM

Part Number DHR-C10
Description AC/DC Current transducer
Manufacturers LEM 
Logo LEM Logo 


There is a preview and DHR-C10 download ( pdf file ) link at the bottom of this page.





Total 3 Pages



Preview 1 page

No Preview Available ! DHR-C10 datasheet, circuit

AC/DC Current transducer DHR-C10
The transducer for the electronic measurement of DC & distorted AC
waveform currents, with galvanic isolation between the primary circuit
(power) and the secondary circuit (measurement). True RMS 0-10V
voltage output.
IPN = 100..1000 A
Electrical data
Primary Nominal
DC & AC Current
IPN (A.t.RMS)
100
200
300
400
500
600
1000
Primary AC Current
Max. Peak Value
IP (A) (*)
600
600
1000
1000
1800
1800
1800
Output voltage
(Analog)
VOUT (VDC)
0-10
0-10
0-10
0-10
0-10
0-10
0-10
R L Load resistance
VC Supply voltage
IC Current Consumption
VSL Output voltage limitation (0-10V)
ÎP Overload capability (Ampere Turns)
Performance data
X
εL
VOE
TCVOE
TCVOUT
tr
BW
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error (1% of IPN .. ± IPN)
Electrical offset voltage, TA = 25°C
Temperature coefficient of VOE ( 0..+60 °C)
(-40..+70 °C)
Temperature coefficient of VOUT (% of reading)
Response time tp 90% of IPN step
Frequency bandwidth (±1dB)
General data
TA
TS
m
IPxx
Ambient operating temperature
Ambient storage temperature
Mass
Protection degree
Type
DHR 100 C10
DHR 200 C10
DHR 300 C10
DHR 400 C10
DHR 500 C10
DHR 600 C10
DHR 1000 C10
10
k
+ 20 .. 50 V DC
30 mA
< 14
V
30000
A.t
< ± 1 % of IPN
< ± 1.0 % of IPN
< ± 1.0 % of IPN
± 2.0 mV/K
± 4.0 mV/K
± 0.1
%/K
< 150
ms
DC 20..6000Hz
- 40 .. + 70
- 40 .. + 85
260
IP20
°C
°C
g
Note :
(*) The Max. Peak AC Current is the highest peak level of the primary signal that is
taken into account for accurate True RMS calculation. Yet the device is designed for
maximum continuous True RMS value equal to IPN, whereas the output is limited by
the above specified output limitation.
Features
VFD and SCR waveforms current
measurement
True RMS output
Panel mounting
Eliminates insertion loss
Insulated plastic case recognized
according to UL94-V0
Advantages
Large aperture for cable up to
Ø32mm
High isolation between primary and
secondary circuits
Easy installation
Applications
VFD Controlled Loads
VFD output indicates how the motor
and attached load are operating.
SCR Controlled Loads
Acurate measurement of phase
angle fired or burst fired (time
proportioned) SCRs. Current
measurement gives faster
response than temperature
measurement.
Switching Power Supplies and
Electronic Ballasts
True RMS sensing is the most
accurate way to measure power
supply or ballast input power.
Application domain
Energy and Automation
061128/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for DHR-C10 electronic component.


Information Total 3 Pages
Link URL [ Copy URL to Clipboard ]
Download [ DHR-C10.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
DHR-C10The function is AC/DC Current transducer. LEMLEM

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

DHR-     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search