Types G3000TF250
Absolute Maximum Ratings
VDRM
VRSM
VDC-link
VRRM
VRSM
VOLTAGE RATINGS
Repetitive peak off-state voltage, (note 1)
Non-repetitive peak off-state voltage, (note 1)
Maximum continuos DC-link voltage
Repetitive peak reverse voltage
Non-repetitive peak reverse voltage
MAXIMUM
LIMITS
2500
2500
1250
18
18
UNITS
V
V
V
V
V
ITGQ
Ls
IT(AV)M
IT(RMS)
ITSM
ITSM2
I2t
di/dtcr
PFGM
PRGM
IFGM
VRGM
Tj op
Tstg
RATINGS
Peak turn-off current, (note 2)
Snubber loop inductance, ITM=ITGQ, (note 2)
Mean on-state current, Tsink=55°C (note 3)
Nominal RMS on-state current, Tsink=25°C (note 3)
Peak non-repetitive surge current tp=10ms, (Note 4)
Peak non-repetitive surge current tp=2ms, (Note 4)
I2t capacity for fusing tp=10ms
Critical rate of rise of on-state current, (note 5)
Peak forward gate power
Peak reverse gate power
Peak forward gate current
Peak reverse gate voltage (note 6).
Operating temperature range
Storage temperature range
Notes:-
1) VGK=-2Volts.
2) Tj=125°C, VD=1250V, VDM 2500V diGQ/dt=40A/µs, ITGQ=3000A and CS=5µF.
3) Double-side cooled, single phase; 50Hz, 180° half-sinewave.
4) Tj(initial)=125°C, single phase, 180° sinewave, re-applied voltage VD=VR10V.
5) IT=3000A repetitive, IGM=30A, diGM/dt=40A/µs. For di/dt>500A/µs please consult the factory.
6) May exceed this value during turn-off avalanche period.
MAXIMUM
LIMITS
3000
200
1690
3460
30
40
4.5×106
500
200
21
100
18
-40 to +125
-40 to +125
UNITS
A
nH
A
A
kA
kA
A2s
A/µs
W
kW
A
V
°C
°C
Data Sheet. Type G3000TF250 Issue A1
Page 1 of 11
March 2013

1 page




G3000TF250 pdf
Anode Shorted Gate Turn-Off Thyristor type G3000TF250
Feedback
R1
Current-
sence
CT
Gate-drive
DUT
0.9VAK
C1 Vs
0.1IA
Not to scale
Diagram 7, Gate trigger circuit and waveforms.
2.6 Turn-on characteristics
The definitions of turn-on parameters used in the characteristic data are given in diagram 8.
Anode current
Gate current
IGT Anode-Cathode
Voltage
diG/dt
IG
IGM
td tr
di/dt
VD
tgt
VD=VDM
ITM
Eon integral
period
Diagram 8, Turn-on wave-diagrams.
2.7 Turn-off characteristics
The definitions of turn-off parameters used in the characteristic data are given in diagram 9.
tgq
tf
0.9
VDM
ITGQ
0.1
IGQ
QGQ
0.1
VG(AV)
VD
VGQ
VGR
Data Sheet. Type G3000TF250 Issue A1
tgw
Diagram 9, Turn-off parameter definitions.
Page 5 of 11
March 2013

5 Page





G3000TF250 arduino
Outline Drawing & Ordering Information
101A316
Anode Shorted Gate Turn-Off Thyristor type G3000TF250
ORDERING INFORMATION
G3000
Fixed
Type Code
TF
Fixed
Outline Code
Order code: G3000TF250
IXYS Semiconductor GmbH
Edisonstraße 15
D-68623 Lampertheim
Tel: +49 6206 503-0
Fax: +49 6206 503-627
(Please quote 10 digit code as below)
25
Fixed Voltage Code
VDRM/100
25
0
Fixed Code
IXYS UK Westcode Ltd
Langley Park Way, Langley Park,
Chippenham, Wiltshire, SN15 1GE.
Tel: +44 (0)1249 444524
Fax: +44 (0)1249 659448
IXYS Corporation
1590 Buckeye Drive
Milpitas CA 95035-7418
Tel: +1 (408) 457 9000
Fax: +1 (408) 496 0670
www.ixysuk.com
www.ixys.com
IXYS Long Beach
IXYS Long Beach, Inc
2500 Mira Mar Ave, Long Beach
CA 90815
Tel: +1 (562) 296 6584
Fax: +1 (562) 296 6585
The information contained herein is confidential and is protected by Copyright. The information may not be used or disclosed
except with the written permission of and in the manner permitted by the proprietors IXYS UK Westcode Ltd.
In the interest of product improvement, IXYS UK Westcode Ltd reserves the right to change specifications at any time without
prior notice.
Devices with a suffix code (2-letter, 3-letter or letter/digit/letter combination) added to their generic code are not necessarily
subject to the conditions and limits contained in this report.
© IXYS UK Westcode Ltd.
Data Sheet. Type G3000TF250 Issue A1
Page 11 of 11
March 2013

11 Page







PáginasTotal 11 Páginas
PDF Descargar[ Datasheet G3000TF250.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
G3000TF250Anode Shorted Gate Turn-Off ThyristorIXYS
IXYS

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar