Datenblatt-pdf.com


RBQ30T65ANZ Schematic ( PDF Datasheet ) - ROHM Semiconductor

Teilenummer RBQ30T65ANZ
Beschreibung Schottky Barrier Diode
Hersteller ROHM Semiconductor
Logo ROHM Semiconductor Logo 




Gesamt 8 Seiten
RBQ30T65ANZ Datasheet, Funktion
Schottky Barrier Diode
RBQ30T65ANZ
lApplication
General rectification
lFeatures
1) Cathode common type.
2) Low IR
3) High reliability
lConstruction
Silicon epitaxial planar
lDimensions (Unit : mm)
10.0±0.3
    0.1
4.5±0.3
    0.1
2.8±0.2
    0.1
1
1.2
1.3
0.8
(1) (2) (3)
ROHM TO220FN
1 Manufacture Date
0.7±0.1
0.05
2.6±0.5
lPackage Dimensions (Unit : mm)
7 540
Data Sheet
lStructure
lAbsolute maximum ratings (Tc= 25°C)
Parameter
Symbol
Reverse voltage (repetitive)
Reverse voltage (DC)
VRM
VR
Average rectified forward current (*1)
Io
Forward current surge peak (60Hz1cyc)
Junction temperature
IFSM
Tj
Storage temperature
Tstg
(*1) Rating of per diode : Io/2
Limits
65
65
30
100
150
-40 to +150
Unit
V
V
A
A
°C
°C
lElectrical characteristics (Tj = 25°C)
Parameter
Forward voltage
Reverse current
Symbol Min.
VF -
IR -
Typ. Max.
- 0.69
- 450
Unit Conditions
V IF=15A
mA VR=65V
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
1/5
2016.09 - Rev.A






RBQ30T65ANZ Datasheet, Funktion
Datasheet
Notice
Precaution on using ROHM Products
1. Our Products are designed and manufactured for application in ordinary electronic equipments (such as AV equipment,
OA equipment, telecommunication equipment, home electronic appliances, amusement equipment, etc.). If you
intend to use our Products in devices requiring extremely high reliability (such as medical equipment (Note 1), transport
equipment, traffic equipment, aircraft/spacecraft, nuclear power controllers, fuel controllers, car equipment including car
accessories, safety devices, etc.) and whose malfunction or failure may cause loss of human life, bodily injury or
serious damage to property (“Specific Applications”), please consult with the ROHM sales representative in advance.
Unless otherwise agreed in writing by ROHM in advance, ROHM shall not be in any way responsible or liable for any
damages, expenses or losses incurred by you or third parties arising from the use of any ROHM’s Products for Specific
Applications.
(Note1) Medical Equipment Classification of the Specific Applications
JAPAN
USA
EU CHINA
CLASS
CLASS
CLASS
CLASSb
CLASS
CLASS
2. ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor
products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate
safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which
a failure or malfunction of our Products may cause. The following are examples of safety measures:
[a] Installation of protection circuits or other protective devices to improve system safety
[b] Installation of redundant circuits to reduce the impact of single or multiple circuit failure
3. Our Products are designed and manufactured for use under standard conditions and not under any special or
extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way
responsible or liable for any damages, expenses or losses arising from the use of any ROHM’s Products under any
special or extraordinary environments or conditions. If you intend to use our Products under any special or
extraordinary environments or conditions (as exemplified below), your independent verification and confirmation of
product performance, reliability, etc, prior to use, must be necessary:
[a] Use of our Products in any types of liquid, including water, oils, chemicals, and organic solvents
[b] Use of our Products outdoors or in places where the Products are exposed to direct sunlight or dust
[c] Use of our Products in places where the Products are exposed to sea wind or corrosive gases, including Cl2,
H2S, NH3, SO2, and NO2
[d] Use of our Products in places where the Products are exposed to static electricity or electromagnetic waves
[e] Use of our Products in proximity to heat-producing components, plastic cords, or other flammable items
[f] Sealing or coating our Products with resin or other coating materials
[g] Use of our Products without cleaning residue of flux (even if you use no-clean type fluxes, cleaning residue of
flux is recommended); or Washing our Products by using water or water-soluble cleaning agents for cleaning
residue after soldering
[h] Use of the Products in places subject to dew condensation
4. The Products are not subject to radiation-proof design.
5. Please verify and confirm characteristics of the final or mounted products in using the Products.
6. In particular, if a transient load (a large amount of load applied in a short period of time, such as pulse. is applied,
confirmation of performance characteristics after on-board mounting is strongly recommended. Avoid applying power
exceeding normal rated power; exceeding the power rating under steady-state loading condition may negatively affect
product performance and reliability.
7. De-rate Power Dissipation (Pd) depending on Ambient temperature (Ta). When used in sealed area, confirm the actual
ambient temperature.
8. Confirm that operation temperature is within the specified range described in the product specification.
9. ROHM shall not be in any way responsible or liable for failure induced under deviant condition from what is defined in
this document.
Precaution for Mounting / Circuit board design
1. When a highly active halogenous (chlorine, bromine, etc.) flux is used, the residue of flux may negatively affect product
performance and reliability.
2. In principle, the reflow soldering method must be used on a surface-mount products, the flow soldering method must
be used on a through hole mount products. If the flow soldering method is preferred on a surface-mount products,
please consult with the ROHM representative in advance.
For details, please refer to ROHM Mounting specification
Notice-PGA-E
© 20165 ROHM Co., Ltd. All rights reserved.
Rev.001

6 Page







SeitenGesamt 8 Seiten
PDF Download[ RBQ30T65ANZ Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
RBQ30T65ANZSchottky Barrier DiodeROHM Semiconductor
ROHM Semiconductor

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche